Error code
F07 DCDC1_START_Failure
F13 Working_Mode_Change
F15 AC_OverCurr_SW_Failure
F16 GFCI_Failure
F18 Tz_AC_OverCurr_Fault
The BUS voltage can’t be reached by PV or battery.
1. Switch off the DC switches and restart the inverter.
The BUS voltage can’t be reached by PV or battery.
1. Switch off the DC switches and restart the inverter.
F04 GFDI_Ground_Failure Check whether the PV is grounded.
F09 IGBT_Failure Restart the inverter 3 times and restore the factory settings.
F10 AuxPowerBoard_Failure
1. First check whether the inverter switch is open.
2. Restart the inverter 3 times and restore the factory settings.
F11 AC_MainContactor_Failure Restart the inverter 3 times and restore the factory settings.
F05 EEPROM_Read_Failure Restart the inverter 3 times and restore the factory settings.
Restart the inverter 3 times and restore the factory settings
F06 EEPROM_Write_Failure
1. When the grid type and frequency have changed it will
report F13.
2. When the battery mode has been changed to "No battery"
mode, it will report F13.
3. For some old FW version, it will report F13 when the
system's work mode has been changed.
4. Generally, this error will disappear automatically.
5. If it remains the same, turn off DC and AC switches for one
EEPROM_Write_Failure
minute, then turn on the DC and AC switches.
AC side over current fault
1. Please check whether the backup load power and common
load power are within the range.
2. Restart and check whether it is normal.
Leakage current fault
1. Check the PV side cable ground connection.
2. Restart the system 2-3 times.
AC side over current fault
1. Please check whether the backup load power and
commonload power are within the range.
2. Restart and check whether it is normal.
F19 Tz_Integ_Fault Restart the inverter 3 times and restore the factory settings.
F08 DCDC2_START_Failure
F12 AC_SlaveContactor_Failure Restart the inverter 3 times and restore the factory settings.
F14 DC_OverCurr_Failure Restart the inverter 3 times and restore the factory settings.
F17 Tz_PV_OverCurr_Fault
1. Check the PV connection and whether the PV is unstable.
2. Restart the inverter 3 times.