4.2 Installation seings (i)
If the installaon seng i01 is not 0, you will be
asked for an access code (000 by default).
Entering the access code: choose the digit using + or -,
conrm with √ and move on to the next digit.
i01: Type of lock
This menu is used to protect access to the installaon and/or user menus
by means of a customisable code.
❶ From the "i01" display, press √ (T4).
❷ Press - or + (T2 or T3) to set the seng value and
conrm your choice by pressing √ (T4).
Access to the
installaon sengs menu
Access to the
user sengs menu
00
- -
01
AUTO
Unlocking by installer
access code (i02)
-
02
AUTO
Unlocking by installer access code (i02)
03
AUTO
Unlocking by installer
access code (i02)
Unlocking by user
access code (U01)
i02 : Installer access code
This menu is used to change the 3-digit installer code ("000" by default),
which is only available if seng i01 is not 0.
The installer code locks access to the following funcons:
• User sengs (if i01=2),
• Installaon sengs
• Associaon and deleon of a wireless product,
- Thermostat reset (return to default sengs),
- Wireless diagnosc display.
❶ From the "i02" display, press √ (T4).
The screen displays "000" The 1st gure ashes.
❷ Press - or + (T2 or T3) to set and press √ (T4) to
confirm and move to the next digit.
❸ Repeat the operaons to determine the 3 digits of
the installer access code.
i21 - i22 - i23: Temperature seing limitation
Heat mode
In heat mode, it is possible to limit the seng range
between a maximum value (i21) and a minimum value
(i22):
i21: max. value (adjustable from i22 to 30°C)
i22: minimum value (adjustable from 5°C to i21)
❶ From the "i21" display, press √ (T4).
The temperature display ashes.
❷ Press - or + (T2 or T3) to set the new value and
press √ (T4) to confirm.
Restart operaons ❶ and ❷ to set i22.
Cool mode
In Cooling mode, you limit the set point below which you do not wish to
drop.
❶ From the “i23” display, press √ (T4).
The temperature display ashes.
❷ Press - or + (T2 or T3) to set the new value and
press √ (T4) to confirm.
T4T3T2T1
T4T3T2T1
T4T3T2T1
The set-point temperature can be adjusted from +5°C to 30°C in
heang mode, and from 10° to 35° in cooling mode.
The values i21-i22 and i23 will be taken into account the next me the
set-point is adjusted from the Tybox Control.
T4T3T2T1
T4T3T2T1
T4T3T2T1