Handleiding
Je bekijkt pagina 6 van 16

Page 5
Unpacking
Please ensure that packaging material is disposed
of in a responsible manner.
Plastic bags should be cut up to prevent children
playing with them and accidentally suffocating.
Remove all packing from the oven cavity and
position the accessories.
If the appliance is damaged in any way, do not
use it. Report the damage to your dealer, who will
take the necessary corrective action.
3. Setup
LPG Gas Only: Do not install this
appliance in a room below ground
level unless it is open to ground level
on at least one side. Failure to install
appliances correctly is dangerous
and could lead to prosecution.
WARNING! ELECTRICAL
CONNECTION MUST ONLY BE
DONE BY A QUALIFIED
ELECTRICIAN
Do not carry the product using the
oven door handle, this may damage
your oven door hinges!
You may lift the product with the door
open by holding the inside of the
oven and the back of the hob.
Gas Installation
The manufacturer and the seller do not accept
responsibility for any damage due to incorrect
installation or gas connection.
Gas bottles should be located outdoors in a
suitable ventilated lock-up. The connecting hose
should not exceed 200 cm in length.
Room size Ventilation opening
Smaller than 5 m
3
min. 100 cm
2
5 m
3
to 10 m
3
min. 50 cm
2
Greater than 10 m
3
not required
In the cellar or basement min. 65 cm
2
Ventilation
Air for combustion is drawn from the room and the
exhaust gases are emitted directly into the room,
therefore good room ventilation is essential for the
safe operation of your appliance. If there is no win-
dow or door available for room ventilation, extra
ventilation must be installed.
The appliance corresponds to device class 1. The
following critical air gaps and ventilation openings
must be maintained:
Connection to the power supply
This appliance should not be connected through
an earth leakage system. Refer to S.A.N.S.
10142.
This appliance has a ‘Y’ type supply cord
connection and must be installed by a licensed
electrician, who will ensure that the stove is
correctly connected and safely earthed.
The rated current is printed on the serial number
label attached to the stove upper back panel.
The appliance must be connected to the mains
through an All pole isolating switch which has a
minimum clearance between the contacts of 3
mm in All poles. A means for disconnection must
be provided in the fixed wiring.
DANGER Risk of explosion!
Before starting any work on the gas
installation, please shut off the gas
supply.
This appliance is supplied ex-
factory with jets and air settings
for use with LPG gas only
A stove without a flame failure
device may only be used with a free
standing cylinder placed adjacent to
but not closer than 300 mm to the
Bekijk gratis de handleiding van Defy DGS578, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Defy |
Model | DGS578 |
Categorie | Fornuis |
Taal | Nederlands |
Grootte | 2350 MB |