INSTALLATION & SERVICE MANUAL FOR PROFESSIONALS
Product description: General description
en
The product label showing the variant and serial number is located next to the USB
connection.
Fig. 4
This section shows the functions of the dierent parts in drain mode A/B. A is the default
mode.
Duct 1
Duct 2 Duct 4
Duct 3
Drain
mode A
Drain
mode B
Duct 5
Duct 6
Fig. 5
Part Mode A Mode B
Duct connection 1 (Fig. 5) Outdoor air - T1 Extract air - T3
Duct connection 2 (Fig. 5) Supply air - T2 Exhaust air - T4
Duct connection 3 (Fig. 5) Extract air - T3 Outdoor air - T1
Duct connection 4 (Fig. 5) Exhaust air - T4 Supply air - T2
Filter 1 (Fig. 3) Exhaust air lter G4 Supply air lter G4 or F7
Filter 2 (Fig. 3) Supply air lter G4 or F7 Exhaust air lter G4
Fan case 1 (Fig. 3) Extract air fan Supply air fan*
Fan case 2 (Fig. 3) Supply air fan* Extract air fan
* Supply fan case may be tted with an electrical preheater (option)
HCV 300 , 400 and 460 have additional ducts in the bottom (ducts 5 and 6) (Fig. 5) which
are closed by default but can be used as a bottom outlet for supply air (T2). The table below
shows which duct is used as the bottom outlet in mode A/B and which corresponding duct
can be closed at the top of the unit. Both ducts can be used simultaneously if desired.
Option for HCV 300/400/460 only:
Drain mode Bottom outlet Duct may be closed
Mode A Duct 5 Duct 2
Mode B Duct 6 Duct 4
Product label
Description of
drain mode A/B
Bottom outlet
in mode A/B