INSTALLATION INSTRUCTIONS
4-WIRE POWER CABLE INSTALLATION
NOTE: Use this method for new branch-circuit-installations (1996 nec), mobile homes, recreational
vehicles, or in an area where local codes prohibit grounding through the neutral wire.
1. Feed the electric cable wires through the flexible metal conduit.
NOTE: Allow enough slack to easily attach the wires to the terminal block.
2. Remove the access panel located on the bottom right-hand side of the back panel to expose the
electrical terminal block.
3. Install a UL listed strain relief to the flexible metal conduit opening in the support brack and fully tighten
the strain relief nut.
4. Feed the flexible metal conduit through the strain relief. Allow enough slack to easily attach the wiring
to the terminal block.
A: Ground Screw
B: Terminal Block
C: UL Listed Strain Relief
IMPORTANT
Only for models sold in the United States. This model does not include a pre-installed power cord. Use
the following wiring instructions before using the range. The power cord is not provided. Follow all
local and national wiring codes and standards.
5. Remove the green jumper wire from under the ground screw and replace with the green wire from the
power cord, tighten ground screw.from the flexible metal conduit and tighten ground screw.
6. Loop the green jumper wire removed from the ground screw back onto its end that is fastened to the
center post on the terminal block.
7. Use a 5/15” nut driver to connect the neutral (white) wire to the center terminal block post with one of
the 10-32 hex nuts.
8. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer posts of the
terminal block with the corresponding red and black wires from the range.
9. Tighten the hex nuts completely and then verify the connection
10. Position the lower part of the strain relief under the flexible metal conduit and tighten the strain relief
screws.
NOTE: Before tightening, make sure the strain relief is positioned over the flexible metal conduit and NOT
the wires.
11. Replace the electrical access panel.
12. Tuck excess conduit into the recessed area of the back panel.