Handleiding
Je bekijkt pagina 45 van 84

Air Conditioner Service Manual
45
accessories.
Note: If the ambient temperature exceeds the range mentioned in the section OPERATION INSTRUCTIONS,
and it can not run COOLING or HEATING mode, lift the front panel and refer to the emergency button
operation to run the COOLING and HEATING mode.
6. Troubleshooting
6.1 Error Code
Code
Reason
Remark
E0
IDU & ODU Communication failure
The IDU & ODU wiring connection correct?
E1
IDU Room Temperature sensor failure. ( IDU RT
failure)
IDU sensor and PCB.
E2
IDU Coil temperature sensor failure. ( IDU IPT
failure)
IDU sensor and PCB.
E3
ODU Coil temperature sensor failure. (OPT)
ODU coil sensor and ODU PCB
E4
AC Cooling system abnormal
Gas leakage? 2-way or 3-way valve blocked
etc.
E5
IDU/ODU mismatched failure (specially
performance test on the production line)
/
E6
IDU PG Fan motor / DC fan motor works abnormal
(IDU failure)
Fan motor, fan blade and PCB.
E7
ODU Ambient Temperature sensor failure
ODU ambient sensor and ODU PCB.
E8
ODU Discharge Temperature sensor failure.
ODU discharge sensor and ODU PCB.