Daikin RXG35K3V1B handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 11 van 20
5 Installation
Installation manual
11
RXS50+60 + RX50+60 + ARXS50~71
R410A split series
3P360062-1H – 2016.09
>250
>300
>100
(mm)
a
a Maximum snowfall height
5.2.2 To install the outdoor unit
M8/M10
5.2.3 To provide drainage
Make sure that condensation water can be evacuated properly.
NOTICE
If the drain holes of the outdoor unit are blocked up,
provide space of at least 300mm below the outdoor unit.
Install the unit on a base to make sure that there is a proper
drainage in order to avoid ice accumulation.
Prepare a water drainage channel around the foundation to drain
waste water surrounding the unit.
Avoid drain water flowing over the footpath, so that it does not
become slippery in case of ambient freezing temperatures.
If you install the unit on a frame, install a waterproof plate within
150 mm of the bottom side of the unit in order to prevent the
invasion of water in the unit and to avoid the drain water dripping
(see the following illustration).
Use a drain plug for drainage if necessary.
a
b
c
d
a Drain hole
b Drain plug
c Bottom frame
d Drain hose (Ø16mm, field supply)
5.2.4 To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1 Prepare 2 cables as indicated in the following illustration (field
supply).
2 Place the 2 cables over the outdoor unit.

Bekijk gratis de handleiding van Daikin RXG35K3V1B, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDaikin
ModelRXG35K3V1B
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3498 MB