8 Troubleshooting
Operation manual
22
LMCEY1A/W + LMCEY2A/W
Daikin LMC
4P753996-1 – 2024.06
Malfunction
Measure
The system operates but
cooling is insufficient.
Check if air inlet or outlet of the unit
evaporator is not blocked by
obstacles. Remove any obstacles
and make sure the air can flow freely.
Check if the evaporator inside the
cold room is not frosted up. Defrost
the unit manually.
Check if there are not too many
articles inside the cold room, see
"5.3 Storing the goods" [4 18]. Don't
overload the cold room.
Check if there is smooth air
circulation inside the cold room.
Reorganise the articles inside the
cold room, see "5.3 Storing the
goods"[418].
Check if there is not too much dust on
the condenser. Remove the dust, see
"7.1.2 To clean the interior" [4 19]To
clean the interior.
Check that the water circuit is not
clogged (only for
LMCEY1W+LMCEY2W).
Check that the plate heat exchanger
is fed with the prescribed water mass
flow (only for
LMCEY1W+LMCEY2W), see
"5.1Operation range"[417].
Check if there is cold air leaking out
of the cold room. Stop the air from
leaking outside.
Check if you did not set the
temperature too high. Set the setpoint
appropriately, see"4.2.3 To set the
temperature"[410].
Check if there are no high-
temperature articles stored in the cold
room. Always store articles after they
have cooled down.
Check if the door is not opened too
long. Reduce the opening time of the
door.
After checking all the items above, if it is impossible to fix the
problem yourself, contact your installer and state the symptoms, the
complete model name of the unit (with manufacturing number if
possible) and the installation date.
8.1
Error codes: Overview
In case a malfunction code appears on the indoor unit user interface
display, check alarm description, effect and troubleshooting. In case
the alarm persist, contact your installer and inform the malfunction
code, the unit type, and serial number (you can find this information
on the nameplate of the unit).
For your reference, a list with malfunction codes is provided. You
can, depending on the level of the malfunction code, reset the code
by pushing the ON/OFF button. If not, ask your installer for advice.
The error codes are visible in the alarm menu.
To access the alarm menu and to reset an alarm or error code, see
"4.5About the alarms"[415].
Display
code
Description Trigger Effect Reset Troubleshooting
CE
Configuration write
error.
Error in writing
parameter. Unvalid
values written into
parameter. Unit was
turned OFF while
parameters writing
was not finshed.
Parameter not saved. Automatic Contact your dealer/installer.