5 | Application guidelines
Installer reference guide
47
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
The higher the outdoor temperature, the better the performance of the
heatpump.
- If energy prices are the same during the day and the night, we recommend to
heat up the DHW tank during the day.
- If energy prices are lower during the night, we recommend to heat up the DHW
tank during the night.
When the heatpump produces domestic hot water, it cannot heat up a space. In
case you need domestic hot water and space heating at the same, we
recommend to produce the domestic hot water during the night when there is
lower space heating demand.
5.4.3 Setup and configuration – DHW tank
For large DHW consumptions, you can heat up the DHW tank several times
during the day.
To heat up the DHW tank to the desired DHW tank temperature, you can use the
following energy sources:
- Thermodynamic cycle of the heatpump
- Electrical booster heater
For more information about:
- Optimizing the energy consumption for producing domestic hot water, see
"9Configuration"[4119].
- Connecting the electrical wiring of the standalone DHW tank to the indoor unit,
see the installation manual of the DHW tank, and the addendum book for
optional equipment.
- Connecting the water piping of the standalone DHW tank to the indoor unit,
see the installation manual of the DHW tank.
5.4.4 DHW pump for instant hot water
Setup
M
b
c
a
f
d
e
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))