5 Operation
Operation manual
9
EPVX10+14S(U)18+23A + EPBX10~14A
Daikin Altherma 4 H F+W
4P773378-1 – 2024.11
Item Description
e Outdoor
e1 Outdoor unit
e2 Quiet operation:
Off
Manual
Scheduled
e3 Quiet operation level:
Quiet
More quiet
Most quiet
e4 Measured outdoor temperature
f Status icons
f1 An error occurred.
f2 A malfunction occurred.
f3 WiFi
WiFi connected
WiFi disconnected
f4 LAN connected
f5 Daikin ONECTA
Connected
Not connected
f6 Daikin HomeHub
Connected
Not connected
Warning
f7 Smart energy enabled
f8 Demo mode is active
g Clock
h Special functions
h1 Holiday
h2 Antifrost
h3 Emergency
h4 Outdoor unit is in locked state. Note: Unlocking
can only be performed by a trained installer.
i Installer switch. To switch between user and installer mode.
User mode
Installer mode
j Navigation / pagination
5.3.2 Main menu screen
Starting from the home screen, swipe left to view the first main menu
screen. Swipe left a second time to view the second main menu
screen From the main menu screens, you can access the different
setpoint screens and submenus.
Main menu screen1:
Malfunctioning
Main zone
Additional zone
Space heating/
cooling
Domestic hot
water
Settings
Information
Commissioning
08:30
25
February
2025
Main menu screen2:
Connectivity
Energy
Configuration
wizard
Touch
Field IO
08:30
25
February
2025
Submenu Description
[11]
Malfunctioning
Restriction: Only displayed if a
malfunction occurs.
See "8.1To display the help text in
case of a malfunction"[416] for more
information.
[1]
Main zone
Shows the applicable symbol for your
main zone emitter type.
Set the leaving water temperature for
the main zone.
[2]
Additional
zone
Shows the applicable symbol for your
additional zone emitter type.
Set the leaving water temperature for
the main zone.
[3]
Space heating/
cooling
Shows the applicable symbol for your
unit.
Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.
[4]
Domestic hot
water
Restriction: Only displayed if a
domestic hot water tank is present.
Set the domestic hot water tank
temperature.
[5]
Settings
Settings for user and installer. Installer
settings are only shown in the installer
mode (the installer switch is in the
position)
[6]
Information
Displays data and information about
the indoor unit.
[7]
Commissioning
Restriction: Only for the installer.
Perform tests and maintenance.
[8]
Connectivity
Restriction: Only for the installer.
Gives access to advanced settings.
[9]
Energy
Shows the electricity consumption.
[10]
Configuration
wizard
Restriction: Only for the installer.
For setting the most important initial
settings.
[12]
Touch
Touchscreen options and testing.
[13]
Field IO
Restriction: Only for the installer.
Terminal pin mapping for certain
functions.