Technician – Parameters
Technician – Parameters
List of parameters P21 to P110
P
No.
Parameter Setting range Factory setting
Own
val-
ues
21 Code no. 0000 to 9999 0000
22 Select system 1 to 13 1
Speed control A1/A2
23 Speed level value Display only
24 Op. mode speed cntrl Auto; Manual Auto
25 Speed level (Manual) 30% to 100% 100%
26
Min. Speed level
(Auto)
30% to 100% 30%
27
Max. Speed level
(Auto)
30% to 100% 100%
28
Diff. temp., 100%
cntrl
10 K to 50 K 35 K
ON/OFF switching differences, hysteresis
30 On switching diff.1 1 K to 30 K 6 K
31 Off switching diff.1 1 K to 30 K 3 K
32 On switching diff.2 1 K to 30 K 6 K
33 Off switching diff.2 1 K to 30 K 3 K
34 Hysteresis reheating 1 K to 30 K 5 K
Special functions
40 En. temp., collector(s) -20°C to +95°C 40°C
41 Dis. temp., collector(s) -20°C to +95°C 35°C
42 Max. coll. temp. 80°C to 180°C 110°C
43
En. temp. 2nd heat
gen.
0°C to 90°C 60°C
44 Max. boiler temp. 30°C to 130°C 90°C
45 Collector safety temp. 80°C to 180°C 110°C
46
Thrshld, tank
Recooling
OFF; 1 K to 30 K OFF
P
No.
Parameter Setting range Factory setting
Own
val-
ues
47
Set temp., tank
(reheat)
10°C to 90°C 40°C
50
Max tank temp.,
tank1
10 °C to 130 °C 60°C
51
Max tank temp.,
tank2
10 °C to 130 °C 60°C
52 Tol. during solar prod. 0 K to 90 K 10 K
53
Hot water short
heating
OFF, 50°C to 70°C OFF
Functions of additional relays A2 and A3
54
Function A2
and/or
Function A3
0 to 8 0
55 Cir. pump on time 1 min to 10 min 1 min
56 Cir. pump blocking 1 min to 20 min 5 min
Return temperature increase
57 Min. return flow temp. 0°C to 90°C 60°C
58 Mixer dynamic Open 5 K to 25 K 18 K
59 Mixer dynamic Close 5 K to 25 K 12 K
Pump kick function (temperature test function)
60 Kick duration OFF; 2 sec to 59 sec OFF
61 Kick pause 10 min to 60 min 30 min
62
Meas. time for 0.5K
incr.
1 min to 5 min 1 min
63
Frost protection
temp.
OFF; -5°C to +5°C OFF
Production estimate/Volume flow counter
70 Pulse rate 0.0 to 100 1.1
71 Pulse rate unit ml/pulse; l/pulse ml/pulse
72 Vol. flow distribution 1:99 to 99:1 50:50
75 Vol. flow - collector1
OFF;
0.1l/min to 100 l/min
OFF