Technician - Electrical connections
Special functions
Depending on the system selected, the outlets A2 and A3 can be
assigned to special functions. The desired function is set with P54
separately for A2 and A3.
Circulation pump
A circulation pump can be activated with parameter P54 = 1, P54
=2 or P54 = 3.
P54 = 1: The circulation pump is switched on permanently during
the enable times (P09 Cir. pump ON time/P10 Cir. pump OFF time).
P54 = 2: If there is a short-circuit at the impulse inlet, the circulation
pump gets switched on for the set switching duration P55. The pump
can be switched on again only after the set reclose blocking period
P56 has elapsed. It is switched on only during the enable times (P09
Cir. pump ON time/P10 Cir. pump OFF time).
P54 = 3: Activation with active Hot water short heating (P53)
A2/A3
P54 = 1
P54 = 2
P54 = 3
A2/A3
Reheating
The reheating function, e.g. using an electric immersion heater, can
be activated using parameter P54 = 4 (storage tank 1) or P54 = 5
(storage tank 2).
The additional heat source is activated when the storage tank tem-
perature at F3 on storage tank 1 (F5 on storage tank 2) drops below
the desired temperature (P47) by (P34).
ڀ Desired temperature with solar production = (P47- P52).
The heat source is switched off again when the temperature of the
storage tank exceeds the desired temperature.
This function is active during the enable time (P07 Reheating ON
Time/P08 Reheating OFF Time).