Daikin DSR1 handleiding

52 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 52
21
Technician - Electrical connections
System 6 (1 collector, 2 storage tanks, 2 charge pumps)
F3F5
F4
F2
F1
A1
A2
A3
A3
Outputs
A1 Charge pump for storage tank 1
A2 Charge pump for storage tank 2
Optional
A3 Additional relay, function can be freely assigned
Inputs
F1 Collector 1 sensor
F2 Tank bottom 2 sensor
F4 Tank bottom 1 sensor
Optional
F3 Tank top 1 sensor
F5 Tank top 2 sensor
Switching conditions A1
ON: Temp
F1
- Temp
F4
> P30 and Temp
F1
> P40,
OFF: Temp
F1
- Temp
F4
< P31 and Temp
F1
< P41.
Switching conditions A2
ON: A1 = OFF
and Temp
F1
- Temp
F2
> P32 and Temp
F1
> P40
OFF: A1 = ON
or Temp
F1
- Temp
F2
< P33 or Temp
F1
< P41