User’s Manual EM11A015H
intelligent Touch Manager
336
Setting
location
Item Setting details
Possible range [
: Visible, : Conditionally visible, × : Invisible]
Remarks
Management point type
Indoor Ventilator Chiller
Dio
Analog
(Ao)
MultiState
(Mo)
outdoor
Indoor unit Hydrobox
AHU
Ventilator
D3Chiller InvChiller Chiller
A/C tab
Airow Direction
Airow direction 0
× × × × × × × × × ×
Airow direction 1
× × × × × × × × × ×
Airow direction 2
× × × × × × × × × ×
Airow direction 3
× × × × × × × × × ×
Airow direction 4
× × × × × × × × × ×
Swing
× × × × × × × × × ×
Timer Extension
ON
× × × × × ×
OFF
× × × × × ×
Setpoint Restriction
Cooling Limit
Enable/Disable
Enable
*9 *9*16 × × × × × × × × ×
Disable
*9 *9*16 × × × × × × × × ×
MAX
Celsius Example: 32°C
*7*9 *7*9*16 × × × × × × × × ×
Fahrenheit Example: 90°F
*7*9 *7*9*16 × × × × × × × × ×
MIN
Celsius Example: 16°C
*7*9 *7*9*16 × × × × × × × × ×
Fahrenheit Example: 60°F
*7*9 *7*9*16 × × × × ×
× × ×
×
Heating Limit
Enable/Disable
Enable
*9 *9*16 × × × × ×
× × ×
×
Disable
*9 *9*16 × × × × ×
× × ×
×
MAX
Celsius Example: 32°C
*7*9 *7*9*16 × × × × ×
× × ×
×
Fahrenheit Example: 90°F
*7*9 *7*9*16 × × × × ×
× × ×
×
MIN
Celsius Example: 16°C
*7*9 *7*9*16 × × × × ×
× × ×
×
Fahrenheit Example: 60°F
*7*9 *7*9*16 × × × × ×
× × ×
×
Ventilator tab
Ventilation Amount
Auto (normal) × × ×
*3*4 × × × × × × ×
When Ventilation
Mode is disabled
for the selected
Ventilator
management point,
the tab itself is
hidden.
Low (normal) × × ×
*3 × × × × × × ×
High (normal) × × ×
*3 × × × × × × ×
Auto (fresh up) × × ×
*3*4*5 × × × × × × ×
Low (fresh up) × × ×
*3*5 × × × × × × ×
High (fresh up) × × ×
*3*5 × × × × × × ×
Ventilation Mode
Automatic × × ×
*3 × × × × × × ×
ERVentilation × × ×
*3 × × × × × × ×
Bypass × × ×
*3 × × × × × × ×
Dio, Ao, Mo tab
Repeat Mode
Enable/Disable
Enable × × × × × × ×
× × ×
Disable × × × × × × ×
× × ×
Interval
1 × × × × × × ×
× × ×
2 × × × × × × ×
× × ×
3 × × × × × × ×
× × ×
4 × × × × × × ×
× × ×
5 × × × × × × ×
× × ×
6 × × × × × × ×
× × ×
7 × × × × × × ×
× × ×
8 × × × × × × ×
× × ×
9 × × × × × × ×
× × ×
10 × × × × × × ×
× × ×
Analog Example: 0.00 × × × × × × × ×
*6
× ×
MultiState Value
Example: Cool/Heat
Recovery
× × × × × × × × ×
×
Cannot be set up
for areas.
HW Supply tab
On/Off(Reheat)
Start ×
× × × × × × × × ×
Stop ×
× × × × × × × × ×
Low Noise
On ×
× × × × × × × ×
Off ×
× × × × × × × ×
Storage Water
Setpoint
Celsius Example: 32°C ×
× × × × × × × × ×
Fahrenheit Example: 90°F ×
× × × × × × × × ×
Other tab
Outer Low Noise
On (On)
Schedule setup
only.
Off (Off)
Capacity value (%)
100
70
40
0
*1 Not displayed when Setback Control is disabled.
*2 Not displayed when Operation Mode (Dry) is disabled.
*3 Not displayed when Ventilation Mode is disabled.
*4 displayed when Ventilation Amount/Auto Air Volume is disabled.
*5 Not displayed when Ventilation fresh up is disabled.
*6 The value will be displayed in set unit, upper/lower limit range, displayed accuracy.
*7 Displayed in °C or °F depending on the unit selected in the System Settings.
*8 Not displayed when R/C Prohibition is disabled in the Service Settings with the central device connected.
*9 Not displayed when Setpoint Restriction is disabled in the Service Settings with the central device connected.
*10 Not displayed when the lter sign is OFF.
*11 Grayed out when Operation Mode is Dry.
*12 Grayed out when Operation Mode is Dry or Fan.
*13 Start/stop of the water heater cannot be controlled.
*14 Start/stop of the water heater behaves as well as “Permitted”.
*15 The storage setpoint is changeable.
*16 The leaving water setpoint and storage setpoint are out of scope.
*17 Not displayed for a heating-only Chiller.
*18 Not displayed for a cooling-only Chiller.
*19 The range of temperatures that can be set up for Setpoint depends on the Chiller model. If a value outside the range is specied from the iTM, it may not be reected in the setting.
*20 The range of temperatures that can be set up for Setpoint depends on the AHU model. If a value outside the range is specied from the iTM, it may not be reected in the setting.
*21 Not displayed when the Dust Alarm is not displayed.
*22 Setting is allowed only when areas that include management points are selected.
Not displayed when management points are selected.
*23 R32 Alarm status: Setting is allowed only for detected management points (not displayed when areas are selected).