11 About the unit and options
Installation and operation manual
12
BS4~12A14AJV1B9
VRV 5 branch selector unit
4P797565-1 – 2024.11
10.1 To remove the accessories
m
3/1x
n
4/2x
o
2x
p
2x
q
2x
r
2x
s
2x
t
2x
u
2x
v
2x
e f g
a b c d
1x
1x 1x 1x
1x 1x 1x
h
3/1x
i
4/2x
j
2x
k
8/11x
l
1x
a Installation and operation manual
b General safety precautions
c Drain hose
d Metal clamp
e Sealing material (large)
f Sealing material (small)
g Sealing material (thin sheet)
h Insulation tube for stopper pipe Ø9.5mm (3× for BS4A,
1× for BS6~12A)
i Insulation tube for stopper pipe Ø15.9mm (4× for BS4A,
2× for BS6~12A)
j Insulation tube for stopper pipe Ø22.2mm
k Tie wraps (8× for BS4A, 11× for BS6~12A)
l Duct closing plate
m Stopper pipe Ø9.5mm (3× for BS4A, 1× for BS6~12A)
n Stopper pipe Ø15.9mm (4× for BS4A, 2× for BS6~12A)
o Stopper pipe Ø22.2mm
p Liquid header reducer pipe (Ø15.9→9.5mm)
q Liquid header reducer pipe (Ø15.9→12.7mm)
r Liquid header expander pipe (Ø15.9→19.1mm)
s Gas header reducer pipe (Ø22.2→12.7mm)
t Gas header reducer pipe (Ø22.2→15.9mm)
u Gas header reducer pipe (Ø22.2→19.1mm)
v Gas header expander pipe (Ø22.2→28.6mm)
11 About the unit and options
11.1 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
11.1.1 Identification label: BS unit
Location
11.2 About the operation range
INFORMATION
For the operation limits, see "13.1.1 Installation site
requirements of the unit"[423].
11.3 System layout
WARNING
The installation MUST comply with the requirements that
apply to this R32 equipment. For more information, see
"12Special requirements for R32 units"[413].
INFORMATION
The following figure is an example and may NOT
completely match your system layout.
a
c
d
f
h
e
d
cc
d
g
h h
b
a Heat recovery outdoor unit
b Branch selector (BS)
c VRV direct expansion (DX) indoor unit
d Remote controller in normal mode
e Remote controller in alarm only mode
f Remote controller in supervisor mode (mandatory in
some situations)
g Centralised controller (optional)
h Option PCB (optional)
Refrigerant piping
Interconnection and user interface wiring
11.4 Combining units and options
INFORMATION
Certain options may NOT be available in your country.
11.4.1 About combining units and options
This BS unit (BS4~12A14AJV1B9) is only compatible with
REMA5+REYA8~20A7Y1B9 units (mind the '9' at the end).
In case the outdoor unit is REMA5+REYA8~20A7Y1B (without a '9'
at the end), contact your dealer to update the software of the outdoor
unit.
11.4.2 Possible options for the BS unit
INFORMATION
All possible options are mentioned in the option list below.
For more information about an option, see the installation
and operation manual of the option.