Daikin BRP069A62 handleiding

52 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 24 van 52
5 | Installation
Installer reference guide
24
BRP069A61+BRP069A62
Daikin Altherma LAN adapter
4P464229-1E – 2023.11
NOTICE
To prevent communication problems due to cable breakdown, do NOT exceed the
minimum bend radius of the Ethernet cable.
5.3.5 To connect the electricity meter
INFORMATION
This connection is ONLY supported by LAN adapter BRP069A61.
1 When entering the wiring from the bottom: inside the LAN adapter casing,
ensure strain relief by routing the cable along the indicated cable path.
2 Connect the electricity meter to LAN adapter terminals X2A/1+2.
S1S
2
1
X4A
X1A
X2A
X3A
INFORMATION
Mind the polarity of the cable. The positive wire MUST be connected to X2A/1; the
negative wire to X2A/2.
WARNING
Make sure to connect the electricity meter in the correct direction, so that it
measures the total energy injected INTO the grid.
5.3.6 To connect the solar inverter/energy management system
INFORMATION
This connection is ONLY supported by LAN adapter BRP069A61.
INFORMATION
How the solar inverter/energy management system is connected to X1A depends on
the Smart Grid application. The connection described in the instructions below is for
the system to run in the "Recommended ON" operation mode. For more
information, see "7Smart Grid application"[437].
WARNING
Make sure X1A/N+L are protected by a fast acting circuit breaker (rated current
100mA~6A, typeB).