4 | Preparation
Installer reference guide
17
BRP069A61+BRP069A62
Daikin Altherma LAN adapter
4P464229-1E – 2023.11
Power line
c
d d
e
X4AX3AP1/P2
a
b
a LAN adapter
b Indoor unit
c Router
d Power line adapter
e Power line
INFORMATION
It is recommended to connect the LAN adapter to the router directly. Depending on
the wireless bridge or power line adapter model, the system might not function
properly.
4.2.2 Indoor unit
For power and communication with the indoor unit, the LAN adapter is connected
to the indoor unit's P1/P2 terminals via a 2‑wire cable. There is NO separate power
supply: the adapter gets its power from the indoor unit's P1/P2 terminals.
4.2.3 Electricity meter
If the LAN adapter is connected to an electricity meter, make sure it is an electrical
pulse meter.
Requirements:
Item Specification
Type Pulse meter
(5VDC pulse detection)
Possible number of pulses 100pulse/kWh
1000pulse/kWh
Pulse duration Minimum On time 10ms
Minimum OFF time 100ms
Measurement type Depends on the installation:
1N~AC meter
3N~AC meter (balanced loads)
3N~AC meter (unbalanced loads)
INFORMATION
It is required that the electricity meter has a pulse output that can measure the total
energy injected INTO the grid.
Suggested electricity meters
Phase ABB reference
1N~ 2CMA100152R1000 B21 212-100
3N~ 2CMA100166R1000 B23 212-100