9 | Electrical installation
Installer reference guide
54
2MXM-A8, 3MXM-A8, 4MXM-A8, 5MXM-A8
R32 Split series
4P766272-5C – 2025.05
Wire type Installation method
Stranded conductor wire
with round crimp-style
terminal
c b ba c
a
B
B
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
Tightening torques
Item Tightening torque (N•m)
M4 (X1M) 1.2
M4 (earth)
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
1-3
9.1.3 Specifications of standard wiring components
Power supply
Voltage 220~240V
Frequency 50Hz
Phase 1~
Current 3MXM40:16.0A
2MXM68:19.8A
3MXM52:16.3A
3MXM68:19.8A
4MXM68:19.8A
4MXM80:20.4A
5MXM90:24.9A
Components
Power supply cable MUST comply with national wiring regulation.
3-core cable
Wire size based on the current, but not less than
2.5mm
2
.
Interconnection cable
(indoor↔outdoor)
Only use harmonised wire providing double insulation
and suitable for applicable voltage.
4-core cable
Minimum size 1.5mm
2