User's Manual
3
Functions Description
Stay Detection
Set the detection area as a polygon with an arbitrary shape.
Set the minimum duration and report interval. Minimum
duration: 1 s60 s; report interval: 1 s600 s.
An alarm is triggered when the stay (loitering) duration exceeds
the defined time for the specified area.
Sleep Detection
Set the detection area as a polygon with an arbitrary shape.
Set the minimum duration and report interval. Minimum
duration: 1 s3600 s; report interval: 1 s3600 s.
An alarm is triggered when an on-duty personnel stays still or lies
down on a table for longer than the set time.
People No. Error
Detection
Set the detection area as a polygon with an arbitrary shape.
Set the minimum duration and report interval. Minimum
duration: 1 s60 s; report interval: 1 s60 s.
Configure detection modes to: 1. Report when people number is
equal to, not equal to, greater than or less than the threshold. 2.
Report when people number is within the range (including the
boundary value) or falls outside the range (excluding the
boundary value). 3. Report on the number of people in an area in
real-time.
When the detection mode is reported with the real-time people
number in the area, the real-time people number will appear on the
left side.
Loudness Detection
After configuring this rule, the client displays the decibel value of
the sound intensity on the video channel in real-time.
Set the decibel value threshold and the duration for triggering
alarms.
An alarm is triggered when the sound intensity is greater than
the defined value (1 dB150 dB) and the sound lasts for the
minimum duration (0 s30 s).
Fighting detection
Set the detection area to a polygon with an arbitrary shape. You
can only set one detection area and one fight rule per video
channel.
1U server supports 16-channel fight detection analysis, overlaid
analysis of fight detection and other rules.
Set the detection sensitivity as a value from 1 to 10. It is 7 by
default.
Staying Alone Detection
Set the detection area as a polygon with an arbitrary shape.
Staying alone alarm can be triggered for each detection area.
Set the minimum duration and alarm interval. Duration: 1 s
1,200 s; alarm interval: 1 s600 s.