COMMAND
Description and Parameters
GET AUTOMATION EVENT N1 UART A COMMAND
Show the currently defined RS-232 command to send when
automation event N1 is triggered.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
SET AUTOMATION EVENT N1 UART A DELAY N2 SEC
Set the delay (in seconds) to wait before triggering RS-232
automation event N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = 0 ~ 240 [Delay in seconds]
GET AUTOMATION EVENT N1 UART A DELAY
Show the currently set delay (in seconds) to wait before triggering
RS-232 automation event N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]