COMMAND
Description and Parameters
SET AUTOMATION EVENT N1 UART A N2
Enable or disable RS-232 automation event type N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = ON, OFF [Enable/Disable event type]
GET AUTOMATION EVENT N1 UART A
Show the current state of RS-232 automation event type N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
SET AUTOMATION EVENT N1 UART A COMMAND N2
Set the RS-232 command to send when automation event N1 is
triggered.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = {Command} [Command to send]