27
2. Input Commands
COMMAND DESCRIPTION AND PARAMETERS
GET IN N1 FORMAT
Show input N1’s current format.
N1 = 1 ~ 4 [Input number]*
Note: Only the currently active input can be
read.
GET IN N1 COLOUR SPACE
Show input N1’s current colour space.
N1 = 1 ~ 4 [Input number]*
Note: Only the currently active input can be
read.
GET IN N1 COLOUR DEPTH
Show input N1’s current colour depth.
N1 = 1 ~ 4 [Input number]*
Note: Only the currently active input can be
read.
GET IN N1 TIMING
Show input N1’s current resolution/timing.
N1 = 1 ~ 4 [Input number]*
Note: Only the currently active input can be
read. Input 4’s state is not available.
GET IN N1 AUDIO
Show input N1’s current audio state.
N1 = 1 ~ 3 [Input number]
Note: Only the currently active input can be
read. Input 4’s state is not available.
SET IN N1 NAME N2
Set the name of input N1.
N1 = 1 ~ 4 [Input number]*
N2 = {Name} [Input name]
GET IN N1 NAME
Show input N1’s name.
N1 = 1 ~ 4 [Input number]*
GET IN N1 EDID DATA
List input N1’s current EDID data in ASCII
HEX.
N1 = 1 ~ 4 [Input number]*
GET IN N1 EDID INFORMATION
Show input N1’s current EDID information.
N1 = 1 ~ 4 [Input number]*