Command: Set the state to change the relay to when this
Automation event is activated.
Duration: Set the length of time, in seconds, to wait before
toggling the relay back to the opposite of the state set under
“Command”. Setting this to 0 will leave the relay state as-is after the
initial change.
6.11.6 EDID Tab
This tab provides control over the EDID settings of all inputs, including
those on specially supported transmitters. This unit provides the option
of three standard EDIDs, one sink sourced EDID and three user uploaded
EDIDs that can be assigned to one input or all inputs as a group. The
names of the user uploaded EDIDs can be changed if desired.
1) User EDID:
Upload: To upload a User EDID, select the User EDID slot to upload
into from the dropdown list and then click the “Upload” button.
An EDID Upload window will appear, allowing you to locate and
upload the preferred EDID file (*.bin format) from a local PC. Once
the correct file has been selected, please click the “Upload” button
in the window, and the file will be transferred to the unit.
Download: To save an existing User EDID to your local PC, select
the User EDID slot from the dropdown list and then press the