COMMAND DESCRIPTION AND PARAMETERS
set webgui login
timeout N1
Set the WebGUI inactivity timeout value.
Available values for N1:
0 [No timeout]
1 ~ 35970 [Timeout in minutes]
get webgui login
timeout
Show the current WebGUI inactivity timeout
value.
set webgui port N1 Set the unit's WebGUI access port.
N1 = 1 ~ 65535 [TCP port]
get webgui port Show the unit's current WebGUI access
port.
set telnet port N1 Set the unit's Telnet access port.
N1 = 1 ~ 65535 [TCP port]
get telnet port Show the unit's current Telnet access port.
set automation event
N1 cec A N2
Enable or disable the specified Automation
Event's CEC response.
Available values for N1:
1 [Power on]
2 [Out A source
active]
3 [Out A source lost]
Available values for N2:
ON [Event enabled]
OFF [Event disabled]