6.3 Remote Control (Optional)
1
POWER Button: Press this button to
power the unit on or off.
Note: The unit will also transmit the
appropriate CEC/RS-232 on/off commands
to any connected displays.
2
OUT A 1~4 Buttons: Press any of these
buttons to immediately switch Output A
to the corresponding input.
3
OUT B 1~4 Buttons: Press any of these
buttons to immediately switch Output B
to the corresponding input.
6.4 RS-232 Pinout and Defaults
Serial Port Default Settings
Baud Rate 19200
Data Bits 8
Parity Bits None
Stop Bits 1
Flow Control None
RS-232 Port A (Unit control) RS-232 Port B
1
2
3
RxD
GND
TxD
3-pin
Terminal Block
1
2
3
RxD
GND
TxD
3-pin
Terminal Block