4) Network: IP mode may be switched between Static IP or DHCP.
In Static IP mode the IP, netmask and gateway addresses may be
manually set. When in DHCP mode, the unit will attempt to connect
to a local DHCP server and obtain IP, netmask and gateway addresses
automatically. Please press “Save after making any changes to the IP
configuration or mode. To return all network settings to their defaults,
press the “Network Reset button.
Note: If the IP address is changed then the IP address required for WebGUI/
Telnet access will also change accordingly.
5) Web Timeout: Select the length of time to wait before logging the
user out of the WebGUI due to inactivity. Available range is from 1 to
120 minutes.
6) Download Current Configuration: The current system configuration,
including routing and settings, may be saved as an XML file to a PC.
Click the “Download” button to save the current system configuration
to your local PC.
7) Restore Configuration: Previously saved system configurations may
be restored from a saved XML file. Click the “Choose File” button to
locate the saved XML file, then click the “Restore button to activate
the selected configuration.
8) Reset to Default: Press the “Reset Status” button to reset the unit to
its factory default state. After the reset is complete, the unit will reboot
automatically into standby mode. Press the “Reset IR Commands
button to only reset and clear out the contents of all uploaded IR
command sets stored in the unit.
9) Firmware Upgrade: To update the units firmware, click the “Choose
File” button to open the file selection window and then select the
firmware update file (*.bin format) located on your local PC. After
selecting the file, click the “Upgrade button to begin the firmware
update process. After the upgrade is complete, the unit will reboot
automatically.