CYP IP-9000RX handleiding

60 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 34 van 60
29
COMMAND
Description and Parameters
4096x2160p50 [4096x2160p50]
4096x2160p60 [4096x2160p60]
1280x720p25 [1280x720p25]
1280x720p30 [1280x720p30]
1280x960p60 [1280x960p60]
2560x1080p50 [2560x1080p50]
2560x1080p60 [2560x1080p60]
2560x1440p50 [2560x1440p50]
2560x1440p60 [2560x1440p60]
2560x1600p60 [2560x1600p60]
get out A resolution
Show the output resolution string for the receiver’s output.
set video wall layout N1 N2
Set the video wall’s total horizontal and vertical display count on receiver.
N1 = 1~16 [Horizontal display count]
N2 = 1~16 [Vertical display count]
get video wall layout
Show the video wall’s current total horizontal and vertical display count on
receiver.
set video wall unit index N1
Set the video wall index number for the connected display on receiver.
(Cannot exceed the video wall’s horizontal and vertical display count.)
N1 = 0~255 [Index]
get video wall unit index
Show the current video wall index number for the connected display on
receiver.
set video wall default
Reset all video wall conguration values to their default settings on receiver.