6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
IP
LINK
POWER
DEFAULT
IR
IPFAC.OUTIN CH. IDCONSOLE
TX RX
IP-9000RX
1 2 3 4 5 6 7 8 9
1
POWER LED: This LED will ash while the unit is powering on and will
illuminate solidly once it is ready to be used.
2
LINK LED: If the receiver has no network connection the LINK LED
will not illuminate. While the receiver is attempting to establish a
connection with a transmitter the LINK LED will ash. When the
receiver has established a stable connection with a transmitter the
LINK LED will illuminate solidly.
3
CONSOLE CTL 3-pin Terminal Block: Connect to a PC, laptop, or
serial controllable device with a 3-pin adapter cable for the extension
of RS-232 signals to the currently routed receiver. The baud rate is
congurable, but the default baud rate is 115200.
Note: When the transmitter is in multicast mode every connected receiver
unit can send RS-232 commands to the transmitter and commands sent
from the transmitter side will be sent to all associated receivers.
4
IR OUT Port: Connect to the provided IR Blaster to transmit IR signals
from the associated transmitter to devices within direct line-of-sight
of the IR Blaster.
5
IR IN Port: Connect to the provided IR Extender to extend the IR
control range of remotely located devices. Ensure that the remote
being used is within direct line-of-sight of the IR Extender.
6
RESET FAC. Pinhole: Press this recessed button to reboot the unit and
all settings will be returned to the factory defaults (Including resetting
the IP mode to auto, broadcast channel to 0, and the streaming mode
to multicast). A new IP address will be assigned automatically within
the 169.254.xxx.xxx address range.
7
RESET IP Pinhole: Press this recessed button to reset the units IP
settings and reboot the unit.