CYP IP-7000H-TX handleiding
Handleiding
Je bekijkt pagina 9 van 48

4
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Transmitter's Front Panel
POWER
RS-232
ISP
SEL
IR
OUT
RESET
IR LINK
LOOPBACK
Anti-DITHER
MODE
ISP
VGA
LOOPBACK
LINK
IR
IN
IP-7000H-TX
1287654321 9 10 11
1
POWER LED: This LED will ash while the unit is powering on and will
illuminate solidly once it is ready to be used.
2
LINK LED: If the transmitter has no network connection the LINK LED
will not illuminate. While the transmitter is attempting to establish
a connection with a receiver the LINK LED will ash. When the
transmitter has established a stable connection with a receiver the
LINK LED will illuminate solidly.
3
RS-232 IN Port: Connect directly to your PC/laptop to send
commands to RS-232 devices connected to the currently routed
receiver. The baud rate is congurable, but the default baud rate is
115200.
Note: When the transmitter is in multicast mode every connected receiver
unit can send RS-232 commands to the transmitter and commands sent
from the transmitter side will be sent to all associated receivers.
4
ISP SEL Switch: This is for factory use only.
Note: By default this is set to the right (away from the RS-232 port) and
allows normal RS-232 functionality. Setting this switch to the left enables
ISP engineering mode.
5
IR OUT Port: Connect to the provided IR Blaster to transmit IR signals
sent from the associated receiver to devices within direct line-of-sight
of the IR Blaster.
6
IR IN Port: Connect to the provided IR Extender to extend the IR
control range of remotely located devices. Ensure that the remote
being used is within direct line-of-sight of the IR Extender.
Note: When the transmitter is in multicast mode the IR signal is sent to all
associated receivers.
7
IR Window: Accepts IR signals from any standard remote control and
sends the signal to the IR Out on the associated receiver.
Note: When the transmitter is in multicast mode the IR signal is sent to all
associated receivers.
Bekijk gratis de handleiding van CYP IP-7000H-TX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.