4
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Transmitter's Front Panel
POWER
LINK RS-232
TXRX
IR LINK
SWITCH
Anti-DITHER
MODE
RESET
ISPISP
SEL
IR
OUT
IR
IN
IP-7000C-TX
87654321 9 1011
1
POWER LED: This LED will ash while the unit is powering on and will
illuminate solidly once it is ready to be used.
2
LINK LED: If the transmitter has no network connection the LINK LED
will not illuminate. While the transmitter is attempting to establish
a connection with a receiver the LINK LED will ash. When the
transmitter has established a stable connection with a receiver the
LINK LED will illuminate solidly.
3
RS-232 3-pin Terminal Block: Connect to a PC, laptop, or serial
controllable device with a 3-pin adapter cable for the extension
of RS-232 signals to the currently routed receiver. The baud rate is
congurable, but the default baud rate is 115200.
Note: When the transmitter is in multicast mode every connected receiver
unit can send RS-232 commands to the transmitter and commands sent
from the transmitter side will be sent to all associated receivers.
4
ISP SEL Switch: This is for factory use only.
Note: By default this is set to the left (towards the RS-232 port) and allows
normal RS-232 functionality. Setting this switch to the right enables ISP
engineering mode.
5
IR OUT Port: Connect to the provided IR Blaster to transmit IR signals
sent from the associated receiver to devices within direct line-of-sight
of the IR blaster.
6
IR IN Port: Connect to the provided IR Extender to extend the IR
control range of remotely located devices. Ensure that the remote
being used is within direct line-of-sight of the IR Extender.
Note: When the transmitter is in multicast mode the IR signal is sent to all
associated receivers.