8
7
HDMI OUT B Port: Secondary HDMI output of the multiviewer
component of the unit. To capture video from the multiviewer
component of the unit, connect this port to the CAPTURE IN port
located directly above it.
8
CONTROL Port: Connect directly, or through a network switch, to
your PC/laptop to control the multiviewer component of the unit via
Telnet/WebGUI.
9
RS-232 Port: Connect directly to a PC, laptop, or other serial control
device with a 3.5mm adapter cable to send RS-232 commands to
control the multiviewer component of the unit.
10
DC 24V Port: Plug the 24V DC power adapter into this port and
connect it to an AC wall outlet to power the multiviewer component
of the unit.
Note: The video capture component of the unit receives power only from
the USB 3.0 connection. Both must be connected to fully power the unit.
6.3 RS-232 Pinout and Defaults (Multiviewer)
Serial Port Default Settings
Baud Rate 19200
Data Bits 8
Parity Bits None
Stop Bits 1
Flow Control None
3.5mm to DE-9
Adapter Cable
RxD
TxD
GND
1
2
3