CYP EL-42PIP handleiding
Handleiding
Je bekijkt pagina 20 van 48

20
6.6.5 OSD Commands
COMMAND
DESCRIPTION VARIABLES
SET OUT A OSD BANNER DISPLAY N1
Enable or disable the OSD info banner. N1 = ON, OFF [Info banner state]
!
Note: Enabling the info banner will automatically disable display of the graphic logo.
GET OUT A OSD BANNER DISPLAY
Show the current state of the OSD info
banner display.
SET OUT A OSD BANNER LOCATION N1
Set the position of the OSD info banner. Available values for N1:
0 [Upper-left]
1 [Middle-left]
2 [Lower-left]
3 [Upper-right]
4 [Middle-right]
5 [Lower-right]
GET OUT A OSD BANNER LOCATION
Show the current position of the OSD
info banner.
SET OUT A INFO LOGO DISPLAY N1
Enable or disable the graphic logo. N1 = ON, OFF [Graphic logo state]
!
Note: Enabling the graphic logo will automatically disable display of the info banner.
GET OUT A INFO LOGO DISPLAY
Show the current status of the graphic
logo display.
SET OUT A INFO LOGO HPOSITION N1
Set the horizontal position of the top
left corner of the graphic logo (in
pixels).
N1 = 0~? [Horizontal position]
!
Note: The maximum value depends on, and cannot exceed, the current output
resolution’s width minus 1.
Bekijk gratis de handleiding van CYP EL-42PIP, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | CYP |
Model | EL-42PIP |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3608 MB |
Caratteristiche Prodotto
Kleur van het product | Zwart |
Gewicht | 3500 g |
Breedte | 438 mm |
Diepte | 269 mm |
Hoogte | 49 mm |