5 — SDO COMMUNICATIONS
Curtis 1352 eXm Manual, June 2021
Return to TOC
pg. 30
DEVICE MONITOR OBJECTS
e following monitor objects are found in the 3100h CAN Object address range, as shown in Table 4.
ese objects all have Read/Write (RW) SDO access, except for the sub-index 00h in a parameter
array, which is Read Only (RO) as indicated.
Table 4 Device Monitor Objects
NAME INDEX SUB-INDEX
RANGE
CAN VALUE
DESCRIPTION
Heatsink Temperature 3110h 00h –40 – 100 °C
–400 – 1000
Temperature of the eXm drivers.
Battery Voltage 3120h 00h 0 – 120 V
0 – 1200
The battery voltage as read by the eXm.
Driver Current 3130h 00h 6 Length of this array (RO).
01h – 06h 0.00 – 3.00 A
0 – 300
Present current sunk by Drivers 1 through 6.
Driver PWM 3131h 00h 6 Length of this array (RO).
01h – 06h 0 – 100 %
0 – 1000
Present PWM % of Drivers 1 though 6.
Hour Meter 3140h 00h 0 – 65535 hrs
0 – 65535
Present value of the hour meter.