5 — SDO COMMUNICATIONS
pg. 25
Return to TOC Curtis 1352 eXm Manual, June 2021
Restore Default Parameters
Restore Default Parameters allows the manager controller to restore all EEPROM backed-up SDO
objects to their Factory (hard-coded in soware), Backup (stored in a secondary/backup EEPROM
section), or Normal settings (stored in EEPROM and accessed by standard SDO). Restore Default
Parameters is also used to restore (Reset) the hour meter value.
Writing a special text string to this sub-index (01h) will initiate a restore to Factory, Backup, or
Normal settings for all EEPROM backed-up SDO objects. Once this parameter is written to, the
next reset (by NMT or cycling power) will cause the system settings to be pulled from the desired
EEPROM locations and put into the working RAM locations (Write String column, below).
An SDO read of Restore Default Parameters Sub-index 01h will return the present settings of Restore
Default Parameters (Read Data column, below).
Restore Default
Parameters Function
Write String Read Data Description
RESTORE_FACTORY_
DEFAULTS
“fact”
74636166h
0 Restore all parameter values from built-in defaults.
These are hard-coded in the software (Factory).
RESTORE_DEFAULTS_
FROM_BACKUP_
EEPROM
“load”
64616F6Ch
1
Restore all parameter values from the Backup set
EEPROM data bank.
RESTORE_NORMAL_
DEFAULTS
“norm”
6D726F6Eh
2 Restore all parameter values from the Normal set
EEPROM data bank.
RESET_HOURMETER “hour”
72756F68h
N/A Reset the hour meter to the value loaded into the
parameter Reset Hour Meter (3040h).
Note that the working parameter values in the eXm RAM will only be restored on the next reset or
power cycle aer the Restore Default Parameters parameter has been written to.
A Restore Defaults from Backup EEPROM command (“load”) will pull the data values from the
Backup EEPROM, place them in RAM, and over-write the settings in the Normal EEPROM.
Whatever changes were made to the Normal EEPROM will be lost. A Restore Normal Defaults
command (“norm”) will allow the eXm to restore from the Normal EEPROM on the next reset or
power cycle.
e hour meter has a special function to reset it. Writing the string “hour” to this index will cause
the eXm to reset the hour meter to the value saved in the Reset Hour Meter parameter (3040h). Note
that only the hours can be set to a programmed value; the minutes will always be reset to 0.