Curtis 1253 Manual, Rev. F
THROTTLE MAP
e rottle Map parameter modifies the response to the throttle input. is
parameter determines the controller output for a given amount of applied
throttle. Setting the throttle map parameter at 50% provides a linear output
response to throttle position. Values below 50% reduce the controller output
at low throttle requests, providing enhanced slow speed control. Values above
50% give the function a faster, jumpier feel at low throttle requests.
e throttle map can be programmed in 5% increments between 20%
and 80%. e number refers to the controller output at half throttle, as a
percentage of the throttles full active range. e throttles active range is the
voltage or resistance between the 0% output point (throttle deadband) and the
100% output point (throttle max). For example, if maximum speed is set at
100%, a throttle map setting of 50% will give 50% output at half throttle. e
50% setting corresponds to a linear response. Six throttle map profiles (20, 30,
40, 50, 60, and 80%) are shown as examples in Figure 10, with the maximum
speed set at 100%.
3 — PROGRAMMABLE PARAMETERS: Throttle Parameters
Fig. 10 rottle maps for
controller with maximum
speed set at 100%.
Lowering the max speed limits the controller’s output range. rottle map
profiles with the max speed reduced from 100% to 80% are shown in Figure 11.
e throttle map is always a percentage of the controllers output range. So, in
these examples, the throttle map is a percentage of the 0–80% output range; a
40% throttle map setting will give 32% output at half throttle (40% of 80% =
32%). Controller output will begin to increase as soon as the throttle is rotated
out of its normal neutral range (deadband). Controller output will continue to
increase, following the curve defined by the throttle map setting, as the throttle
input increases and will reach maximum output when the throttle input enters
the upper deadband (crosses the throttle max threshold).
100908070605040302010 0
100
90
80
70
60
50
40
30
20
10
0
SPEED PARAMETER
100% Thrtl Max Speed
80%
60%
50%
40%
30%
20%
THROTTLE MAP
THROTTLE INPUT (percent of active range)
CONTROLLER OUTPUT (PWM percent)