HIGH CURRENT CONNECTIONS
ere are four high-current terminals, identied on the controller housing as B+, B–, M1 and M2.
High Current Connections
Terminal Function
B+ Positive battery to controller (after the main contactor)
B– Battery Negative to the controller
M1 Motor Terminal 1
M2 Motor Terminal 2
Table 1 The High Current Terminal Connections
Lug assembly: high current connections
e power connections are aluminum. Assemble the cables using M6 bolts sized to provide proper
engagement illustrated in Figure 4.
• Place the lug on top of the aluminum terminal, followed by a high-load safety washer with its
convex side on top. e washer should be a SCHNORR 416320, or equivalent.
• When using two lugs on the same terminal, stack them so the lug carrying the least current is
on top.
• Tighten the assembly to 10.2 ±1.1 Nm (90 ±10 in-lbs.).
Figure 4
e high-current terminal assembly
M6 BO LT
HIGH L OAD
SAFETY WASHER
LUG
M6 TERMINAL
SECTION VIEW
EXPLODED VIEW
6 mm MIN
THREAD ENGAGEMENT
9.2 mm
MAX
THREAD ENGAGEMENT
High current wiring recommendations
Battery cables (B+, B–)
Route the battery cables close to each other between the controller and the battery. Use high quality
copper lugs and observe the recommended torque ratings. For best noise immunity, do not route
the cables the across the center section of the controller. On systems with multiple high current
controllers, use a star-ground format from the battery B– terminal.