3 — PROGRAMMABLE PARAMETERS
Curtis Model 1226BL – July 2024 Return to TOC
pg. 64
MISC MENU
e following table describes the parameters on the Misc menu.
MISC MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Password Enable
0x510000
Disable/Enable
Disable
0–1
8-bit
Indicates whether the feature to password-protect
parameter values is enabled.
The Password menu is visible when password protection
is enabled.
Restore Parameters
0x507601
−32768 − +32767
0
−32768 − +32767
16-bit
Resets all parameters to their factory default values. To
reset the parameters, specify any value except 1, then cycle
the keyswitch.
Update Supervisor
0x700101
0–1
0
0–1
16-bit
The primary microprocessor stores an image of the
supervisor microprocessor’s firmware. To use the image to
update the supervisor firmware, specify 1.
Drivers Setting Menu
e following table describes the parameters on the Drivers Setting menu.
DRIVERS SETTING MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Coil Supply Enable
0x515400
Off/On
On
0–1
8-bit
Species whether the coil supply output is enabled.
If Off is specied, the Coil Supply output cannot be turned off if
the lift or lower driver shorts.
CAUTION: Specifying Off may make the system non-compliant
with EN 1175:2020 and may cause a higher probability of
dangerous failure. Regulatory compliance of the complete
vehicle system, including this setting, is the responsibility of the
vehicle OEM.
EM Brake Driver Checks Enable
0x341B01
Off/On
On
0–1
8-bit
Species whether the controller checks the driver for the
open condition:
On = If the open condition occurs, the controller opens the
driver and generates the EM Brake Driver Fault.
Off = The controller does not check for the open condition.
CAUTION: Specifying Off may make the system non-compliant
with EN 1175:2020 and may cause a higher probability of
dangerous failure. Regulatory compliance of the complete
vehicle system, including this setting, is the responsibility of the
vehicle OEM.
Pump Contactor Driver Checks
Enable
0x341C01
Off/On
On
0–1
8-bit
Species whether the controller checks the driver for the
open condition:
On = If the open condition occurs, the controller opens the
driver and generates the Pump Driver Fault.
Off = The controller does not check for the open condition.
CAUTION: Specifying Off may make the system non-compliant
with EN 1175:2020 and may cause a higher probability of
dangerous failure. Regulatory compliance of the complete
vehicle system, including this setting, is the responsibility of the
vehicle OEM.