3 — PROGRAMMABLE PARAMETERS
pg. 37
Return to TOC Curtis Model 1226BL – July 2024
CURRENT LIMITS MENU
Use the Current Limits parameters to limit the current supplied by the controller during driving,
regenerative braking, and emergency reverse operations.
e following table describes the menu's parameters.
Note: e parameter values are percentages of the controller’s fully rated current.
CURRENT LIMITS MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Drive Mode
0x533300
Enumerated
Traction Mode
0–1
8-bit
Species the drive mode for the current loop:
0 = Traction Mode
1 = Electric Cylinder Mode
Drive Current Limit
0x344101
10–100%
100%
3276–32767
16-bit
Species the maximum current the controller supplies to the
motor during driving.
Note: Reducing the current limit reduces the maximum drive torque.
Regen Current Limit
0x344501
10–100%
50%
3276–32767
16-bit
Species the maximum current the controller supplies to the
motor when regenerative braking occurs.
Reverse Drive Current Limit
0x533400
10–100%
100%
3276–32767
16-bit
Species the maximum current the controller supplies when
the vehicle is driving in the reverse direction.
The parameter is available when Drive Mode species Electric
Cylinder Mode.
Reverse Regen Current Limit
0x533500
10–100%
60%
3276–32767
16-bit
Species the maximum current the controller supplies when
regenerative braking occurs while the vehicle is driving in the
reverse direction.
The parameter is available when Drive Mode species Electric
Cylinder Mode.
EMR Current Limit
0x344301
10–100%
50%
3276–32767
16-bit
Species the maximum current the controller supplies to the
motor during emergency reverse.
Interlock Brake Current Limit
0x345E01
10%–100%
70%
3276–32767
16-bit
Species the maximum current the controller supplies to the
motor during interlock braking.
When interlock braking is active, the current limit is specied by
whichever of the following parameters species a higher value:
• Interlock Brake Current Limit
• Regen Current Limit
Boost Enable
0x343301
Off/On
On
0–1
8-bit
Indicates whether the boost current function is enabled.
Boost current provides a brief increase of current to improve
performance with transient loads such as starting on a hill,
crossing a threshold, climbing obstacles, etc.
Boost Time
0x343501
1.0–10.0s
10.0s
63–625
16-bit
Species the maximum duration of a boost current event.
Bekijk gratis de handleiding van Curtis 1226BL, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.