Curtis 1226BL handleiding
Handleiding
Je bekijkt pagina 42 van 124

3 — PROGRAMMABLE PARAMETERS
Curtis Model 1226BL – July 2024 Return to TOC
pg. 34
Throttle Response Parameters
e Forward and Reverse Deadband, Max, and Map parameters specify the controller output that is
generated at various throttle voltages. e Forward and Reverse Oset parameters dene the output
generated by the controller when the throttle is rst rotated out of the neutral deadband. ese
parameters dene the throttle’s responsiveness.
e following diagram shows the relationship between these parameters, the throttle’s wiper voltage,
and the controller output. e diagram is for a throttle with a 5.0V maximum voltage.
Figure 7
rottle Response
Parameters
e following list describes the parameters to which the diagram refers:
• Deadband = 10%. e vehicle is in neutral until the throttle’s voltage is 0.5 volts (10% of 5.0V)
• Oset = 0%. A 0% value means there is no controller output when the throttle’s voltage rst
exceeds 0.5 volts.
• Max = 90%. e controller output reaches 100% when the throttle is at 4.5V (90% of 5.0V)
• e points in the Map parameter lines represent the controller outputs for various Map values
when the throttle’s voltage equals 2.5V (50% of 5.0V).
Note: You can use the rottle Pot Percent and rottle Command variables to monitor the throttle
voltage and controller output.
Bekijk gratis de handleiding van Curtis 1226BL, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Curtis |
Model | 1226BL |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 15971 MB |