3 — PROGRAMMABLE PARAMETERS
Curtis Model 1226BL – July 2024 Return to TOC
pg. 34
Throttle Response Parameters
e Forward and Reverse Deadband, Max, and Map parameters specify the controller output that is
generated at various throttle voltages. e Forward and Reverse Oset parameters dene the output
generated by the controller when the throttle is rst rotated out of the neutral deadband. ese
parameters dene the throttles responsiveness.
e following diagram shows the relationship between these parameters, the throttles wiper voltage,
and the controller output. e diagram is for a throttle with a 5.0V maximum voltage.
Figure 7
rottle Response
Parameters
e following list describes the parameters to which the diagram refers:
Deadband = 10%. e vehicle is in neutral until the throttles voltage is 0.5 volts (10% of 5.0V)
Oset = 0%. A 0% value means there is no controller output when the throttles voltage rst
exceeds 0.5 volts.
Max = 90%. e controller output reaches 100% when the throttle is at 4.5V (90% of 5.0V)
e points in the Map parameter lines represent the controller outputs for various Map values
when the throttles voltage equals 2.5V (50% of 5.0V).
Note: You can use the rottle Pot Percent and rottle Command variables to monitor the throttle
voltage and controller output.