2 — INSTALLATION AND WIRING
pg. 5
Return to TOC Curtis Model 1220E – August 2022
You will need to take steps during the design and development of your end product to ensure that its
EMC performance complies with applicable regulations; suggestions are presented in Appendix A.
The 1220E controller contains ESD-sensitive components. Use appropriate precautions in
connecting, disconnecting, and handling the controller. See installation suggestions in Appendix A
for protecting the controller from ESD damage.
CONNECTIONS: High Current
Four 1/4” Faston terminals are provided for the high current
connections. The motor connections (M1, M2) and battery
connections (B+, B–) have one terminal each.
CONNECTIONS: Low Current
e low current connections are made through three connectors: J1, J2, and J3.
J1 J2 J3
4 3
2 1
8 5
4 1
14 8
7 1
J1-4 Pin
Molex:39-28-8040
1 Rx
2 I/O GND
3 Tx
4 +12V
Mating connector: Molex 39-01-2040 with appropriate 45750-series crimp terminals
J2-8 Pin
Molex:
39-28-8080
1 Home Switch 2
2 Interlock Input 2
3 Command Encoder 2A
4 Command Encoder 2B
5 Steer Motor Encoder 2A
6 Steer Motor Encoder 2B
7 CAN TERM H
8 Auxiliary Analog Input
Mating connector: Molex 39-01-2080 with appropriate 45750-series crimp terminals
M1 M2 B- B+