A command map is used in the input command signal ow to compensate for steering geometry
dierences between vehicles (steered wheel on the le side, middle, or right side). e command
map menu contains 14 parameters dening an 8-point map that modies the steer command input.
e rst point [Le Stop (deg)] always denes the steer command input of -100% and the last point
[Right Stop (deg)] always denes the steer command input of 100%.
COMMAND MAP
NAME
ALLOWABLE
RANGE RAW DATA DESCRIPTION
Left Stop
(0x335000, 16bits)
–120.0° – 0°
–21845 – 0
Denes the steer command output of full left.
P1 Input
(0x335100, 16bits)
–100.0% – 0%
–16384 – 0
Denes the steer command input in % for P1 Input.
P1 Output
(0x335200, 16bits)
–120.0° – 0°
–21845 – 0
Denes the steer command output in degree for P1 Output.
P2 Input
(0x335300, 16bits)
–100.0% – 0%
–16384 – 0
Denes the steer command input in % for P2 Input.
P2 Output
(0x335400 16bits)
–120.0° – 0°
–21845 – 0
Denes the steer command output in degree for P2 Output.
P3 Input
(0x335500, 16bits)
–100.0% – 0%
–16384 – 0
Denes the steer command input in % for P3 Input.
P3 Output
(0x335600, 16bits)
–120.0° – 0°
–21845 – 0
Denes the steer command output in degree for P3 Output.
P4 Input
(0x335700, 16bits)
0% – 100.0%
0 – 16383
Denes the steer command input in % for P4 Input.
P4 Output
(0x335800, 16bits)
0° – 120.0°
0 – 21844
Denes the steer command output in degree for P4 Output.
P5 Input
(0x335900, 16bits)
0% – 100.0%
0 – 16383
Denes the steer command input in % for P5 Input.
P5 Output
(0x335A00, 16bits)
0° – 120.0°
0 – 21844
Denes the steer command output in degree for P5 Output.
P6 Input
(0x335B00, 16bits)
0% – 100.0%
0 – 16383
Denes the steer command input in % for P6 Input.
P6 Output
(0x335C00, 16bits)
0° – 120.0°
0 – 21844
Denes the steer command output in degree for P6 Output.
Right Stop
(0x335D00, 16bits)
0° – 120.0°
0 – 21844
Denes the steer command output of full right.