Curtis 1212 handleiding
Handleiding
Je bekijkt pagina 9 van 47

2 — INSTALLATION AND WIRING
pg. 5
Return to TOC 1212 Manual – Sept. 2022
CONNECTIONS: High Current
Four 1/4" Faston terminals are provided for the high current connections.
e motor connections (M1, M2) and battery connections
(B+, B–) have one terminal each.
CONNECTIONS: Low Current
e low current logic control connections are provided by a 14-pin connector. e mating connector
is a Molex Mini-Fit-Jr. receptacle p/n 39-01-2140 with appropriate 45750-series crimp terminals.
J1
1234567
8910 11 12 13 14
J1 Pin 1
pot wiper
J1 Pin 2
pot high
J1 Pin 3
horn
J1 Pin 4
mode switch (open=M1, closed=M2)
J1 Pin 5
keyswitch input (KSI)
J1 Pin 6
speed inhibit
J1 Pin 7
B+
J1 Pin 8
pot low
J1 Pin 9
speed pot
J1 Pin 10
status LED
J1 Pin 11
BDI
J1 Pin 12
reverse switch
J1 Pin 13
I/O GND
J1 Pin 14
push switch
A 4-pin low power connector is provided for the programmer and the battery
charger. e mating connector is a Molex Mini-Fit-Jr. receptacle p/n 39-01-2040 with
appropriate 45750-series crimp terminals. (A mating connector is provided with the
handheld programmer.).
A 2-pin low power connector is provided for the electromagnetic brake. e mating
connector is a Molex Mini-Fit-Jr. receptacle p/n 39-01-2020 with appropriate
45750-series crimp terminals.
M1 M2 B– B+
12
34
J2
J2 Pin 1 Rx
J2 Pin 2 I/O GND
J2 Pin 3 Tx/charge inhibit
J2 Pin 4 B+
J3 Pin 1 Brake +
J3 Pin 2 Brake -
1
2
J3
Bekijk gratis de handleiding van Curtis 1212, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.