On models equipped with a timer, the red indicator (see Figure 3-4) in the manual side of the
TIMED/MANUAL selector switch will go out when the idle timer disrupts power to the heating circuit. This
indicator will be lit whenever the unit is in MANUAL mode and is cooking normally.
B. HIGH EFFICIENCY UNITS - “ES” MODELS
Model 24CGA6.2SES and 24CGA10.2ES are steamers designed for high efficiency operation. The
energy saver models provide steam in a similar manner to our high capacity models except that the flow
of steam is regulated by cycling the burners off once the desired cooking temperatures is reached. When
the temperature drops to a set point below the desired cooking temperature the burners will turn back on
to bring the cooking compartment back up to temperature. The burners will continue to cycle on and off
as necessary to maintain temperature until the cooking operation is complete.
CHAPTER 4 CONTROL PANELS
The standard dial timer control panel (illustrated in Figure 4-1) has a mechanical timer. An optional
electronic keypad timer, illustrated in Figure 3-2, and an ON/OFF control panel (not illustrated) are also
available. The Electronic and mechanical timers use a temperature compensation circuit, which allows the
timer to count down only while the cooking compartment is at cooking temperature. The ON/OFF Control
Panel, which is not illustrated, operates exactly like the timed models in manual mode, except a selector
switch is used to turn the steam to the cooking compartments ON and OFF.
A. DIAL TIMER CONTROL PANEL
1. Cooking Operations – Dial Timer Control Panel
For safe, efficient operation of the steamer, the operator must, at a minimum, comply with all cautions,
warnings and instructions in the detailed operating procedures and be familiar with the control panel shown
in Figure 3-1. The operator must be familiar with all the operating features explained in this manual before
attempting to operate the steamer.
2. Manual and Timed Modes
The steamer has two operating modes: manual and timed. The TIMED/MANUAL rocker switch selects the
operating mode. Pressing the MANUAL end of the switch selects the manual operating mode. Pressing the
TIMED end of the switch selects the timed operating mode. Cooking procedures are slightly different for
each mode.
a. Manual Mode
The manual mode provides continuous cooking. The operator starts and stops steaming operations
manually. See the Operating and Cooking Procedure – Manual mode in Chapter 4, Part B for more
information. A thermostat controlled pause light located on each control indicates that the cooking
compartment has not yet reached cooking temperature.
Note: These units are equipped with an energy saver timer, that will automatically, shut the
burner system down when a cooking compartment is left ON (ON/OFF Models), or left in
MANUAL mode (TIMED models) for more than one hour. This one hour timer is reset whenever
the unit is switched to TIMED (or switched OFF) and back to MANUAL mode (or back ON)
depending on the steamer control type, or whenever the door is opened. As usage of the steamer
will frequently reset this timing function during normal usage, it should generally function only
when equipment has been left steaming (ON) and unattended for long periods between shifts, or
if exceedingly long cook times are required. In the later case, operating personnel will need to be
aware of this feature, so that the timer can be reset by opening and closing the door during such
prolonged cook periods. On models equipped with a timer, the red indicator in the manual side of
the TIMED/MANUAL selector switch will go out when the idle timer disrupts power to the heating
circuit.