Cleco NeoTek T55-3000021 handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 32
10 P2407MA | 2019-06 Apex Tool Group
1
EN
5 LED signals
6 Ambient conditions
EMC Limit Class A (electromagnetic immunity for industrial areas)
Only for use indoors
Recommendation: ESD workstation on installation
7 Troubleshooting
LED color Explanation
Continuously green Measurement was successful.
Flashing green Bootloader active.
Waiting for application.
If the LED does not stop flashing after 5-10 seconds, the application is
defective, see 7 Troubleshooting, Page 10.
Continuously red Measurement has failed.
See Troubleshooting.
Continuously white Software update is running.
Continuously yellow Measurement is running.
Feature Data
Ambient temperature 0 °C … 45 °C
Storage temperature -25 °C … 70 °C
Humidity 10% … 90%, non-condensing
Protection Class
DIN EN 60529
IP40
Problem Possible cause Measure
Accessory does not work Accessory not activated by software See Troubleshooting
Accessory not properly installed Check installation
Accessory defective Replace accessory
Tool defective Replace tool
Wrong software on TIM Perform software update with
correct software
Wrong software on STMD-H Perform software update with
correct software
TIM defective Send tool for repair
Application is not
loaded
Measurement card software is not
recognized
Use correct measurement card
software
No application on the tool Perform software update with
correct software
CAN bus communication not
possible
Make sure the tool is installed
correctly
Make sure the correct TIM soft-
ware is used