TRANSMIG 4RT INSTALLATION/SETUP
INSTALLATION/SETUP 3-20 Manual 0-5245
3.12 Attaching the Tweco Professional MIG Torch (Euro)
1. Align the pins on the MIG Torch Cable with the pin holes of the MIG Torch receptacle on the front of the system.
Press the MIG Torch in and secure by turning the locking ring to the right (clockwise). Refer to Figure 3-8.
Attach MIG Torch. Turn
locking ring to the right
Art # A-11284
Figure 3-10: Mount MIG Torch Cable to Adapter Socket
2. If equipped, align the keyways of the MIG Torch Switch connector pigtail with the 8 pin receptacle to the right
of the MIG Torch cable and plug them together. Secure by turning the locking ring to the right (clockwise).
Refer to Figure 3-10.
NOTE
When disconnecting the MIG Torch trigger switch leads from the machine, Do Not pull on the wires. Loosen
the locking ring and gently pull the plug out of the socket.