DVM27U Series Installation Instructions
12
Installation of First Row of Uprights
NOTE: The mount should be installed from bottom to top,
installing the entire bottom row first before building up
as needed.
NOTE: Refer to dimensions drawings on pages 5-10 for further
details on installation locations. Corresponding
measurement worksheet may be printed and filled out
for quick reference as measurements are made.
1. Determine mounting locations for first set of uprights using
formulas found on measurement worksheets (pages 8-10).
a. Horizontally
Odd number of columns: From centerline to
middle column = (MPW/2) - 2.875" (73mm).
Even number of columns: From seam or edge of
display = [(DW-MPW/2)] + 2.875" (73mm).
b. Vertically
2-High
Display edge to bottom mounting point =
[1(DH) - 10.28" (261.1mm)].
Display edge to top mounting point =
[1(DH) - 10.28" (261.1mm)] + 20.57
(522.5mm).
3-High
Display edge to bottom mounting point =
[1.5(DH) - 16.93" (430mm)].
Display edge to top mounting point =
[1.5)DH) - 16.93" (430mm)] + 33.86
(860mm).
4-High
Display edge to bottom mounting point =
[2(DH) - 23.57" (598.7mm)].
Display edge to top mounting point =
[2(DH) - 23.57" (598.7mm)] + 47.14"
(1197.5mm).
3. Draw level horizontal lines at vertical locations determined
in Step 2b using a 4-foot level or a laser level. (See Figure 2)
IMPORTANT ! : Make sure to include the above finished
floor measurement (AFF) in the calculation to determine
mounting locations.
The DVM27U wall mounts are designed to be mounted to the
following wall types:
Table 1: Fastener Information
IMPORTANT ! : The following Steps show installation to
drywall attached to plywood-backed wall. For installation
into concrete, Fischer Anchor UX10x60R (CF) must be used
with 3/8" mounting holes. See Fastener Installation Methods
Section for details.
4. Mark mounting hole location along upper line based on
horizontal locations determined in Step 2a. (See Figure 2)
5. Drill a 7/32" at the location of the first upper mounting hole.
(See Figure 2)
Figure 2
6. Use 5/16 x 2 1/2" hex head lag screw (CA) and 5/16"
washer (CE) to loosely install left upright (A) to wall. Center
the lag bolt horizontally along mounting slot. PARTIALLY
tighten bolt. (See Figure 3)
Figure 3
WALL TYPE PILOT
HOLE
FASTENERS (see PARTS
drawing)
Drywall attached
to plywood-
backed walls
Steel/Wood
studs
7/32" x
3"
- 5/16 x 2-1/2" flanged hex head
lag (CA)
- 5/16" flat washer (CE)
Concrete or
concrete block
3/8" x
3"
- 5/16 x 2-1/2" flanged hex head
lag (CA)
- 5/16" flat washer (CE)
- Fischer Anchor UX10x60R (CF)
3
7/32"
4 5
(CA)
(A)
6
(CE)