- To remove the lter, press on the tabs as shown in Figure 9 and pull it out.
Carbon lter
This type of lter has activated carbon and puries air and absorbs cooking odours. The
activated carbon becomes saturated after a period of time, which will reduce the adsorption
capacity of the lter. The carbon lter cannot be washed nor cleaned in any way. When its
service life comes to an end you must replace it with a new one.
- It is recommended to check the condition of carbon lters regularly, at least two or three
times a year. Its replacement will depend on how the kitchen hood is used, as well as the
daily operating time.
- In case of very frequent frying, shorten the time interval for checking and/or replacing the
carbon lters.
Installing the carbon lters
1. Remove the protective metal lters.
2. The carbon lters are located on both sides of the motor. Insert and turn the lters, until
they are rmly in place.
3. To replace the carbon lter, proceed in reverse order.
4. The carbon lter must not be exposed to heat.
Fig. 2 10:
A: Closed
B: Opened
C: Opened
D: Closed
Carbon lter diameter:
Article No 02859/02860/02861 > 132 mm
Article No 02862 > 176 mm
Replacing the light bulb/lamp
Please note:
- The light bulb must be replaced by the ocial Cecotec Technical Support Service or
similarly qualied technicians.
- Always disconnect the power supply before performing any operation on the appliance.
When handling the bulb, make sure that it has cooled down completely before any direct
contact with your hands.
- When handling the bulbs, hold them with a cloth or gloves to prevent sweat from coming
into contact with the bulb, as this may reduce the bulb life.
Note:
- Before changing the light bulb, make sure that the appliance is switched o and unplugged.
- Protect yourself from danger when changing the light bulb, e.g., by wearing gloves.
6. TROUBLESHOOTING
Fault Cause Solution
The indicator light is
on, but the motor does
not work
The kitchen hood is
obstructed
Remove what is obstructing the
hood
The condenser is damaged Please contact the ocial Cecotec
Technical Support Service to
replace the condenser.
Motor is jammed or bearing
damaged
Please contact the ocial Cecotec
Technical Support Service to
replace the motor.
Motor is burnt or gives o a
bad smell
Please contact the ocial Cecotec
Technical Support Service to
replace the motor.
Neither the light bulb
nor the motor work
In addition to the above, check the following:
The light bulb has blown Please contact the ocial Cecotec
Technical Support Service to
replace the light bulb.
Power cable is loose Please contact the ocial Cecotec
Technical Support Service to
connect the cables according to the
wiring diagram.
Grease falls out of the
aluminium lters
The lters are very dirty Clean or replace the aluminium
lters immediately
The kitchen hood
vibrates
The fan is damaged, causing
the kitchen hood to vibrate
when extracting air.
Please contact the ocial Cecotec
Technical Support Service to
replace the fan.
The engine is not securely
fastened
Fix the engine correctly
The kitchen hood is not
securely fastened
Fix the kitchen hood correctly