cnReach N500 User Guide System Configuration
phn-4980_001v004 August 2019)
2-65
Slope and Offset are both treated as floats, and must be valid float values. The defaults are slope=1,
offset=0, thus having no affect on the value.
Special is the arbitrary math function that can be applied to the value. If it is not used, ensure that it is
empty, no spaces or other characters. To use it, put a function of the form y=”f(x)”, where the quoted
part is entered into the box. Examples are “!x”, to invert the incoming data, “123*x+456”, a slope/offset
calculation, etc. A slope/offset calculation is valid, but is not reversible if entered here, as opposed to
the defined slope/offset are properly reversed on a write. The letter “x”, lower case, is the input to the
function. This supports addition (+), subtraction/negation (-), multiplication (*), division (/),
exponentiation (^) and modulus (%) with the normal operator precedence, abs, acos, asin, atan, atan2,
ceil, cos, cosh, exp, floor, ln, log, log10, pow, sin, sinh, sqrt, tan, tanh, fac, ncr, npr, with constants e and
pi available. Constants can be integers, decimal numbers, or in scientific notation (e.g. 1e3 for 1000).
IMPORTANT: If this value will be written, ie a Modbus Master will write to the data concentrator output
map, and the data concentrator will write through to the defined device/poll/register, then the special
function must be reversible, or not used. “!x” is reversible (for bit like numbers), in that !1 = 0, and !0 =
1. Most other arbitrary math is not reversible.
Output Value Setup
The output map defines a register, then a source which is a tag name comprised of the
Device.Poll.Value. The advanced button hides another slope/offset/special set of data manipulations
that can be used. This set of slope/offset/special is only applied to the Modbus output registers, not
MQTT values.
Coil/Discrete:
Holding/Inputs:
Note:
• All Modbus registers are in protocol address (0-65534), not PLC address (1..., 10,001…, 30,001…,
40,001…)
• Writing only supports (0x05) Write single coil, (0x06) Write single holding register, and (0x10)
Write multiple holding registers.