Handleiding
Je bekijkt pagina 4 van 20

4
1. TECHNICAL DATA
1.1 AIR DISTRIBUTION (NORMAL OPERATION)
1.3 D
EFROST CYCLES TABLES
HRV150S UNIT
OUTDOOR TEMPERATURE DEFROST CYCLES (MINUTES)EXTENDED DEFROST CYCLES
FAHRENHEIT (°F) DEFROSTING
OPERATION TIME BETWEEN EACH
DEFROST CYCLES
DEFROSTING
OPERATION TIME BETWEEN EACH
DEFROST CYCLES
23 7 50 10 30
5 7 25 10 20
-17 10 20 10 15
1.2 AIR DISTRIBUTION (DEFROST MODE)
VF0052
VF0053
ERV180S UNIT
OUTDOOR TEMPERATURE DEFROST CYCLES (MINUTES)EXTENDED DEFROST CYCLES
FAHRENHEIT (°F) DEFROSTING
OPERATION TIME BETWEEN EACH
DEFROST CYCLES
DEFROSTING
OPERATION TIME BETWEEN EACH
DEFROST CYCLES
23 10 60 10 30
510301020
-17 10 20 10 15
HRV190S UNIT
OUTDOOR TEMPERATURE DEFROST CYCLES (MINUTES)EXTENDED DEFROST CYCLES
FAHRENHEIT (°F) DEFROSTING
OPERATION TIME BETWEEN EACH
DEFROST CYCLES
DEFROSTING
OPERATION TIME BETWEEN EACH
DEFROST CYCLES
23 6 50 10 30
5 6 25 10 20
-17 10 20 10 15
NOTE: The HRV and ERV Performance Charts are listed on the specification sheets of these units.
Visit our website at www.broan-nutone.com to access those documents.