CAUTION
To reduce risk of fire and to properly exhaust air, be sure to duct air outside - Do not vent
exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
For ADA compliance installation guidelines, please use kit HAWSK5 for GLA3, MTR3, ALT3 &
ALT4 series. Visit Broan website for installation instruction (
ADA Instructions Intermediate Hoods)
Installation Preparation
Recommended Tools and Accessories for Installation:
Measuring tape
Phillips screwdriver no. 2
Nutdriver or socket 11/32"
• Flat blade screwdriver (to open knockout holes)
• Drill,1/8” drill bit and1½” hole saw (to mark holes for ducting and cut electrical
access hole)
• Wood shims (2) and wood screws (4) (required for standard installation to framed
cabinet)
• Saw (to cut holes for ducted application)
• Sheet metal shears (ducted installation only, for duct adjustment)
• Pliers (ducted installation only, for duct adjustment)
• Metal foil duct tape (for ducted applications)
Scissors (to cut metal foil duct tape)
Pencil
Wire stripper
• Strain relief,1/2” diameter (to secure house wiring cable to the hood)
• BP87Q Damper (needed if 7-in. round duct is used)